GEOTHERM WGB (3P) 2,5

Specifications

Specifications Units of phys. qt Standard size
Boiler type 2,5
Heating capacity kW 2500
Water temperature at the exit of the boiler ◦С 95
110 
150
at the entrance to the boiler 70
70 
70
EC (efficiency coefficient) of boiler Natural gas % 94,8
94,2  93
diesel 92,6 91,5 
90,9
Fuel consumption Natural gas Nm3/h 263
265 268
diesel kg/h 228
230  233
Exhaust gas temperature Natural gas ◦С 136 145  171
diesel 170  183  208
Aerodynamic resistance of the boiler (without burner) Pa 720 735 
740
Hydraulic resistance MPа 0,13 0,14 
0,11
Design water pressure at the inlet MPа 0,7    0,9 
1,6
Water flow through the boiler t/h 86
53,7  27
Specific emission of nitrogen oxides Natural gas g/m³ 0,08 
0,08  0,08
diesel 0,16
0,16  0,16
Adjustment range % 30-100 30-100
30-100
Boiler weight (without burner, without water) kg 4240 4200 
4200
Water volume of boiler 0,86 0,85
0,85
Heating surface area 86,4 86,4
86,4

PRODUCT DESCRIPTION

GEOTHERM ® WGB (3P) series boilers are designed to produce hot water. Boilers are focused on heat supply of industrial and domestic facilities.

GEOTHERM ® WGB (3P) series boilers are produced with three temperature schedules 70-95 °C; 70-110 °C; 70-150 °C.

Boilers of the GEOTHERM ® WGB (3P) series are produced with a capacity of 0.25 to 15 MW.

The fundamental difference between the boilers of the GEOTHERM ® WGB (3P) series from the boilers of the GEOTHERM WGB(P); GEOTHERM WMB; GEOTHERM WGB(V) series is that the exhaust gases after burning the torch of the burner unfold in the furnace, pass through the fiston, unfold again and pass through the convective surface. The main advantage of boilers of this series is that they can be used to replace old equipment during the reconstruction of boiler houses because boilers of the GEOTHERM ® WGB (3P) series have a small overall size in length. The small overall size in length is achieved by the fact that the convective surface is located above the boiler furnace, and not behind it as in GEOTHERM ® WGB (P) series boilers.





Main components of GEOTHERM ® WGB (3P) series boilers:

  • Collector frame - serves to distribute water flows depending on the hydraulic circuit of the boiler and the connection of the boiler to the external strapping.
  • The convective section is the main part of the boiler pipe system.
  • The support frame serves as the base for the installation of the boiler pipe system.
  • Stiffness belt - serves as a frame to ensure the rigidity of the boiler.
  • The flue duct with an explosive valve - serves as a channel for the discharge of exhaust gases.

The GEOTHERM WGB (3P) 2,5 hot water boiler is installed with burners from the world's leading manufacturers. Operates on two sources of fuel: natural gas and diesel fuel.